BTP2 - Control - Automated Biogas Test Facility
The biogas pilot plant BTP2 Control is used in the academic field and for substrate or gas yield tests. Furthermore, this system is ideally suited for product development (enzymes, nutrients) or for process optimization. This system is characterized by a high degree of equipping and automation.
TTo request more information and prices call + 49 351 88646-00 or e-mail us: info@uit-gmbh.de.
- Bioreactors, volume 15 liters, different volumes on request
- Continues operation with AUTO feeding (Optional)
- Electric heating with control
- Dosage pumps for pH-value control (Optional)
- Powerful agitators with two stirrers
- Gas meter to measure gas quantity
- Gas Quality Measurement (CH4, CO2, H2S, O2)
- Central data acquisition
- Bio reactor with various installation ports
- Silicon – heater band
- Feeding system
- Stirrer including speed adjustment and display of torque
- Gas tight shaft feed
- Gas bag for gas sampling
- Assembly frame
- Measuring equipment (pH-Value / Redox-Potential (Optional) / temperature)
- T-Controller device
- Temperature measuring equipment
- Redox measuring equipment
- Recording of gas quantities through gas meters
- Automatic gas analysis system
- Software package Biogas-control
Area of application
- Research
- Fermentation yield test
- Optimization of gas outout
Advantages
- On-line measuring equipment
- System expandable up to 10 reactor units
- Integrated gas analysis
- Data storage and visualization
- Simultaneous recording of gas quality and quantity
- Central data acquisition and control unit
- Customized equipping and automation-degree
- Compact, space-saving rack systems
Bioreactor with Measuring Technique and Stirrer | |
---|---|
Dimensions | Vol. approx. 15 liter; outer diameter: 270 mm, wall thickness: 9 mm, height: 350 mm; differnt volumes on request |
Material / Configuration | For measuring equipment |
Max. allowed Temperature | 60°C |
Feeding | Feeding funnel (stainless steel) including dipped duct and sealing plug |
Shaft feed through | Variant 1: dipped duct |
Variant 2: surge tank | |
Heating | Silicon-heater band incl. temperature sensor, Height of heater band: 200 mm; max. input power for heating: 500 W Adjustment of heating system through T-control unit |
Measuring Equipment for Bioreactor | |
pH-value | Measuring range: 1-14; Length: 220 mm, PG 13.5 screw-in thread |
Redox potential (ORP) | Option: Measuring range: - 2000...+2000 mV; length: 220 mm, PG 13.5 screw-in thread |
Temperature | Measuring range: 0...60°C, resolution: 0.1 °C, sensor screwed-in |
Stirrer / Stirrer features | |
Speed range | 10 – 500 rpm |
Torque | Max. 600 Ncm |
Display | Speed and torque |
Stirrer tools | 2 levels with propeller shaped stirrers and anchor shaped stirrers |
Gas Counter / Gas Bag | |
Measuring range | 1…60 l/h; resolution: 2,5 ml |
Gas Bag | Volume 10 liter as sample for gas quality measurement |
Gas Quality Measurement System | |
CH4 | Range: 0...100 Vol. %; measuring principle: IR |
CO2 | Range: 0...100 Vol. %; measuring principle: IR |
H2S | Range: 0...5000 ppm; principle: electro-chemical - one range |
O2 | Range: 0...25 Vol. %; principle: electro-chemical measuring cell |
Features | Gas cooler |
SENSOcontrol | |
Storage and Display Unit | pH-value, temperature and gas amount – incl. graphical and tabular display of actual values |
Control Values | Asynchronous timing of the agitator Option: pH control using of several 2-channel peristaltic pumps |
Software Features | |
Software | Biogas-control |
Space Requirements | |
Modules | Width: 50 cm; Depth: 65 cm; Height: 240 cm – for each module |
Zcentered Gas Quality Measurement Modul with PC | Width: 115 cm; Depth: 65 cm; Height: 240 cm |
Illustrations and descriptions may vary. The plant / product is subject to change depending on technical updates.
We will gladly give you an individual offer.
Anfrageformular
Latest modification: 03.06.2021