Highlights
Retardation Plant
Retardation plant to separate process solutions and acid baths from unwanted ions.
Separation: up to 60% in one passage (higher separation rates by repeated cycles); acid recovery: 80%
rack based plant including the frame
To request more information and prices call + 49 351 88646-00 or e-mail us: info@uit-gmbh.de.
Advantages:
- Recovery of Acids
- Operating life time of process baths will be increased
- meet of critical values by recovery of acids instead of neutralisation (sulphate, chloride)
| Technical Data | |
|---|---|
| Application | Retardation, Ion-Exchange, bath maintenance, separation of non-wanted ions |
|
Amount columns
|
1 - 10 |
| Resin | Lewatit, particel size 0,6 mm |
| Reaction volume | 2000 liter |
| Flow capacity | 3 - 5 m³/h |
| Limitation pH-value | <0 - 12 |
| Material | column: GRP, tanks: PP, seals: FPM |
| Dimensions | length x width x hight ca. 6060 x 2440 x 2900 mm |
| Pre-filtration | optional, 5µm |
| Elektrical Parameter | |
| Connection | 400 V, 50 Hz, max. 5 kW |
| Controlled technology | 2 x frequency converted pump |
| ready-for-connection control cabinet Optional: control panel inclusive Siemens PLC |
|
| Messtechnik | |
| Level control | 2 x pressure sensor |
| Level control overfull | 2 x vibronic level switch |
| Quality measurement | 2 x pH-value measurement (alternatively: conductivity) |
| Pressure measurement | 2 x after each pump |
Illustrations and descriptions may vary. The plant / product is subject to change depending on technical updates.
We will gladly give you an individual offer.
Anfrageformular
Latest modification: 22.03.2018