Submersible Probes - One Parameter Probes
Submersible probes with integrated amplifier are robust, easily connectable single probes with analog output and wide range power supply, preferably used for connection to data loggers.
To request more information and prices call + 49 351 88646-00 or e-mail us: info@uit-gmbh.de.
Filed of application
- Surface water
- Ground water
- Sewer monitoring
- Process monitoring
Advantages
- Integrated signal amplifier
- Easy installation
- Analog output
- Directly connectable with different types of data logger
- Wide voltage range for power supply
- Low power consumption
- Low cost maintenance
- Frequent and long-term measuring without human intervention
- Reliable and accurate measurement data
- Easy calibration
Submersible measuring Probes with integrated signal amplifier | |
---|---|
CTD probe (conductivity, temperature, depth) with signal amplifier | - Relative pressure sensor, range: 0 - 10 m (other ranges on request) - Conductivity sensor, range 0 - 20 mS/cm (other ranges on request) - Temperature sensor 2 °C … + 60 °C - Analog signal output for CTD - Power supply: 4.5 - 12 VDC - Probe cable with air compensation tube - Diameter: 22 mm, length 320 mm |
pH-value / redox potential probe with signal amplifier | - pH-value sensor with ceramic diaphragm or redox sensor with PT cup - pH-value range 1 … 14, redox range - 2,000 … + 2,000 mV - Measuring amplifier installed in the casing - Analog signal output and RS 485 output - Power supply: 5 - 14 DC - Length: 435 mm - Casing diameter: 40 mm |
DO probe (dissolved oxygen) with signal amplifier | - DO sensor, Clark electrode - Range 0 - 20 mg/l - Measuring amplifier installed in the casing - Analog output and digital output RS 485 - Power supply: 5 - 14 DC - Length: 435 mm - Casing diameter: 40 mm |
Nitrate, ammonia, chloride probe with signal amplifier | - Measuring probe for nitrate or ammonia or chloride - Type: ion selective - Range for nitrate: 0.68 … 68,000 mg/l (5 decades) - Range for ammonia 0.18 … 18,000 mg/l (5 decades) - Range for chloride 0.35 … 35,000 mg/l (5 decades) - Measuring amplifier installed in the casing - Analog output and digital output RS 485 - Power supply: 5 - 14 DC, Ø casing: 40 mm, length: approx. 435 mm |
Water level probe with signal amplifier | - Relative pressure sensor, range: 0 - 10 m (other ranges on request) - Option: temperature sensor 2 °C … +60 °C - Analog signal output - Power supply: 4.5 - 6.5 VDC (12 V power supply on request) - Probe cable with air compensation tube - Diameter: 22 mm, length 150 mm |
Illustrations and descriptions may vary. The plant / product is subject to change depending on technical updates.
We will gladly give you an individual offer.