SENSOsampler- Sampling System

The compact measuring station for water quality is a combination of measuring probes with an automatic water sampler. The compact measuring station is equipped with a data logger and includes remote data transmission. The water sampler and data loggers are installed in a field cabinet and thus robustly housed. Sampling can be triggered automatically or by time.

To request more information and prices call +49 351/88646-00 or e-mail us: info@uit-gmbh.de.

  Field case
  Dimensions   140 cm x 85 cm x 145 cm
  Material   Steel with isolation
  Type   Lockable
  Automatic sampler
  Bottles   24 x 1 litre suction
  Sampling system   Vacuum system; suction head up to 6.5 m at 1.013 hPa air pressure
  Sampling method   Time-controlled and/or alarm triggered
  Probes Option 1 - SENSOdive
  Sensors   3 Sensors plus installable pressure and temperature and ext. sensors
  Relative pressure sensor   0 ... 10 m; 0 ... 20 m; 0 ... 50 m; 0 ... 100 m water level
  Absolute pressure sensor   800 - 2,100 mbar; 800 - 6,100 mbar; 800 - 11,100 mbar
  Temperature sensor   0 °C ... 50 °C; resolution: 0.04 °C
  Conductivity sensor  
  • 0 ... 20 mS/cm; resolution 1 μS/cm or
  • 0 ... 0.2/2/20/500 mS/cm; resolution up to 0.1 μS/cm
  pH   1 ... 14, resolution ΔpH = 0.01
  Redox potential   -2,000 ... +2,000 mV; resolution 1 mV
  pH/Redox – combination sensor   pH 1 ... 14; redox –2,000 ... +2,000 mV
  DO [O2] – luminescence   0 ... 40 mg/l O2; resolution 0.02 mg/l O2
  Ion selective sensors   Chloride, nitrate, ammonia and bromide – specification on request
  External sensors   Turbidity; chlorophyll – only with data logger LogTrans7-compact or Logtrans-field
  Probes Option 2 - MSM-S2
  Sensors   6 Sensors plus pressure and temperature and ext. sensors configurable
  Absolute pressure sensor   800 ... 2,100 mbar; 800 ... 6,100 mbar; 800 ... 11,100 mbar
  Temperature sensor   0 °C ... 50 °C; resolution: 0.04 °C
  Conductivity sensor   0 ... 200 mS/cm; resolution 1 μS/cm or 0- 0,2/2/20/500mS/cm; resolution up to 0,1 µS/cm
  pH   –2,000 ... +2,000 mV; resolution 1 mV
  pH/Redox – combination sensor   pH 1 ... 14; redox –2,000 ... +2,000 mV
  DO [O2] – luminescence   0 ... 40 mg/l O2, resolution 0.02 mg/l O2
  Turbidity   0 - 25/125/500/2500 NTU
  Ion selective sensors   Chloride, nitrate, ammonia and bromide – specification on request
  External sensors   Turbidity; chlorophyll
  Data logger
  Option   LogTrans-field - specification see Link
  Power supply   Accumulator 12V/60 Ah
  Solar power supply   Option

Illustrations and descriptions may vary. The plant / product is subject to change depending on technical updates.

We will gladly give you an individual offer.

Anfrageformular


Latest modification: 23.09.2022